Home/Articles/Technology
Technology25 September 2025·6 min read

Indoor air quality: the central role of ventilation

CO2, VOCs, filtration... How ventilation delivers healthy air and what the commissioning engineer's obligations are.

🗺️ Find HVAC experts near you📋 Submit my project request
🌿
Metteur au Point Team
metteuraupoint.fr
Indoor air quality: the central role of ventilation

We spend 80 to 90% of our time indoors. Indoor air quality (IAQ) has become a major public health issue, brought into sharp focus by the pandemic. The HVAC commissioning engineer plays a central role: they are the ones who ensure ventilation systems deliver the regulatory fresh air rates.

Indoor pollutants

  • • CO₂ (carbon dioxide): an indicator of poor ventilation. The recommended threshold is 1,000 ppm (French order of 2 May 2023). Above that, concentration drops and drowsiness sets in.
  • • VOCs (volatile organic compounds): emitted by building materials, furniture and cleaning products. Formaldehyde is the most closely monitored (threshold: 30 µg/m³).
  • • Fine particles (PM2.5, PM10): from outdoors (traffic, industry) or indoors (cooking, printers).
  • • Radon: a naturally occurring radioactive gas, mainly in granite areas. The threshold is 300 Bq/m³.

Regulations and fresh air rates

  • • Order of 24 March 1982 (French regulation): sets minimum ventilation rates in dwellings (e.g. 135 m³/h peak rate for a 4-room home).
  • • French labour code (R4222-6): minimum 25 m³/h per person in offices, 45 m³/h in workshops.
  • • NF EN 16798-1: the European standard that classifies IAQ into 4 categories (I to IV) and defines the associated airflow rates.
  • • Decree no. 2015-1000: mandatory IAQ monitoring in public-access buildings (schools, nurseries) with CO₂ and formaldehyde measurement.

The commissioning engineer's role

  • • Check fresh air rates at every supply terminal (flow hood, anemometer).
  • • Check ductwork air-tightness to prevent leakage of polluted air.
  • • Check that motorised dampers and fresh air dampers work correctly.
  • • Measure CO₂ levels in occupied rooms to validate the air change rate.
  • • Make sure filtration is appropriate (ISO ePM1 55% minimum in commercial buildings according to EN ISO 16890).
FIELD TIP

Install a CO₂ sensor in meeting rooms during commissioning: it is the simplest way to prove the ventilation is working properly and to persuade the facility operator not to cut airflow rates.

Need an HVAC commissioning engineer?

Find qualified HVAC experts on the interactive map or post a project request.

Expert mapPost a project request

Are you a commissioning engineer?

Join the network of HVAC experts in France. Receive project requests, grow your business and raise your profile.

Join the network

Further reading

🌀
Air balancing an MVHR system: a step-by-step method
Balancing · 7 min
🌬️
AHUs: anatomy and commissioning of an air handling unit
Commissioning · 8 min
📖
HVAC standards and DTUs: the commissioning engineer's key references
Regulations · 7 min

Related articles

🔧
10 essential measuring instruments for HVAC commissioning engineers
6 min · 22 January 2026
🖥️
BMS and building controls: the key role of the commissioning engineer
7 min · 10 January 2026
📐
BIM and HVAC: the digital model as a commissioning tool
7 min · 8 October 2025